6.1 Basic Operation
6-19
6
Reference Pulse/Feedback Pulse Counter Monitor Display
The monitor display of reference pulse counter and feedback pulse counter is expressed in
32-bit hexadecimal.
The display procedure is as follows:
Using the Hand-held Digital Operator
1. Press the DSPL/SET Key to select the monitor mode.
2. Press the Up or Down Cursor Key to select “Un00C” or “Un00D.”
3. Press the DATA/ENTER Key to display the data for the monitor number selected in the
above step 2.
4. Press the Up or Down Cursor Key to alternately display the leftmost 16-bit data and
rightmost 16-bit data.
5. Press both the Up and Down Cursor Keys simultaneously to clear the 32-bit counter
data.
6. Press the DATA/ENTER Key once more to return to the monitor number display.
Using the Panel Operator
1. Press the MODE/SET Key to select the monitor mode.
2. Press the Up or Down Cursor Key to select “Un00C” or “Un00D.”
3. Press the DATA/SHIFT Key for a minimum of one second to display the data for the
monitor number selected in the above step 2.
4. Press the Up or Down Cursor Key to alternately display the leftmost 16-bit data and
rightmost 16-bit data.
5. Press both the Up and Down Cursor Keys simultaneously to clear the 32-bit counter
data.
6. Press the DATA/SHIFT Key once more for a minimum of one second to return to the
monitor number display.
Leftmost 16-bit Data
Rightmost 16-bit Data
MODE/SET
DATE/
Leftmost 16-bit Data
Rightmost 16-bit Data