Yaskawa Large Capacity Sigma II Series User Manual
Page 132

4 Parameter Settings and Functions
4.3.3 Input Circuit Signal Allocation
4-56
• Allocating Other Input Signals
Input signal allocation can be changed as shown below.
Table 4.1 Allocation of Other Input Signals
Input Signal
Parameter
Description
Name
Applicable
Logic
Number
Setting
Proportional Control
Reference
(/P-CON)
ON (low level)
Pn50A.2
0
Inputs the signal on the left from the SI0 (CN1-40).
1
Inputs the signal on the left from the SI1 (CN1-41).
2
Inputs the signal on the left from the SI2 (CN1-42).
3
Inputs the signal on the left from the SI3 (CN1-43).
4
Inputs the signal on the left from the SI4 (CN1-44).
5
Inputs the signal on the left from the SI5 (CN1-45).
6
Inputs the signal on the left from the SI6 (CN1-46).
7
Sets the signal on the left to always enabled.
8
Sets the signal on the left to always disabled.
9
Inputs the reverse of the signal on the left from the SI0 (CN1-40).
A
Inputs the reverse of the signal on the left from the SI1 (CN1-41).
B
Inputs the reverse of the signal on the left from the SI2 (CN1-42).
C
Inputs the reverse of the signal on the left from the SI3 (CN1-43).
D
Inputs the reverse of the signal on the left from the SI4 (CN1-44).
E
Inputs the reverse of the signal on the left from the SI5 (CN1-45).
F
Inputs the reverse of the signal on the left from the SI6 (CN1-46).
Forward Run Prohibit
(P-OT)
OFF
(high level)
Pn50A.3
0 to F
Same as above. *
Reverse Run Prohibit
(N-OT)
OFF
(high level)
Pn50B.0
0 to F
Same as above. *
Alarm Reset
(/ARM-RST)
ON
(low level)
Pn50B.1
0 to F
Same as above. *
Forward Current Limit
(/P-CL)
ON
(low level)
Pn50B.2
0 to F
Same as above. *
Reverse Current Limit
(/N-CL)
ON
(low level)
Pn50B.3
0 to F
Same as above. *
Contact Input Speed
Control Selection
(/SPD-D)
-
Pn50C.0
0 to F
Same as above. *
Contact Input Speed
Control Selection
(/SPD-A)
-
Pn50C.1
0 to F
Same as above. *
Contact Input Speed
Control Selection
(/SPD-B)
-
Pn50C.2
0 to F
Same as above. *
Control Mode Selec-
tion (/C-SEL)
ON
(low level)
Pn50C.3
0 to F
Same as above. *
Zero Clamp
(/ZCLAMP)
ON
(low level)
Pn50D.0
0 to F
Same as above. *