beautypg.com

6 checking the motor model, Using the hand-held digital operator – Yaskawa Large Capacity Sigma II Series User Manual

Page 255

background image

6.2 Applied Operation

6-35

6

6.2.6 Checking the Motor Model

Set the parameter Fn011 to select the motor model check mode. This mode is used for the
motor maintenance, and can also be used to check the specification codes of SERVOPACKs
made with special specifications.

Follow the procedure below to check the motor model.

Using the Hand-held Digital Operator

1. Press the DSPL/SET Key to select the auxiliary function mode.

2. Select the parameter Fn011. Press the Left or Right Cursor Key to select the digit. Press

the Up or Down Cursor Key to change the number.

3. Press the DATA/ENTER Key to display the servomotor model and voltage code.

4. Press the DSPL/SET Key to display servomotor capacity.

Voltage

Servomotor Model

Code

Voltage

Code

Servomotor Model

00

100 VAC or 140 VDC

00

SGMAH

01

200 VAC or 280 VDC

01

SGMPH

02

400 VAC or 560 VDC

02

SGMSH

03

SGMGH-†A (1500 min

-1

)

04

SGMGH-†B (1000 min

-1

)

05

SGMDH

06

SGMUH

0B

SGMBH

Servomotor model

Voltage

Capacity: Displayed value

× 10 (W)

In this example, the capacity is 100 W.