Manual Gain Adjustment of Analog Monitor Output
Follow the procedure below to execute the manual gain adjustment of analog monitor out-
put.
Using the Hand-held Digital Operator
1. Press the DSPL/SET Key to select the auxiliary function mode.
2. Select the parameter Fn00D. Press the Left or Right Cursor Key to select the digit.
Press the Up or Down Cursor Key to change the number.
3. Press the DATA/ENTER Key. The following display will appear.
4. Press the DSPL/SET Key, and the monitor output for the two channels will be displayed
alternately as shown below.
5. Press the Left or Right Cursor Key to display the analog monitor gain constant. Pressing
the Left or Right Cursor Key again will return to the display shown in the above step 3.
or 4.
6. Press the Up or Down Cursor Key to adjust the gain for the analog monitor output.
7. When the gain adjustment has been completed for the two channels, press the DATA/
ENTER Key to return to the auxiliary function mode display.
This completes the manual gain adjustment of the analog monitor output.