8.2 Troubleshooting

8-9

8

„

A.30

A.30: Regenerative Error Detected

Display and Outputs

Note: OFF:Output transistor is OFF (alarm state). ON: Output transistor is

ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

ON

ON

OFF

OFF

Cause

Remedy

A

Regenerative transistor is abnormal.

Replace SERVOPACK.

B

Disconnection of the regenerative resistor.

Replace SERVOPACK or regenerative
resistor.

C

Regenerative Unit disconnected (for an
external regenerative resistor).

Check wiring of the external regenerative
resistor.

D

SERVOPACK defective.

Replace SERVOPACK.

A, B

A, B, C

D

During servomotor
operation

Occurred approximately 1
second after the main
circuit power ON.

Occurred when the
control power turned ON