7.5 Specifications and Dimensional Drawings for Peripheral Devices

7-53

7

JUSP-DB06 Dynamic Brake Unit

„

Connections

Using a Yaskawa Dynamic Brake Unit

• SGDH-2BDE, 3ZDE SERVOPACKs

The dynamic brake contactor and Surge Absorption Unit are built into the SERVO-

PACK. Connect the DU, DV, and DW terminals and the Frame Ground (

) on the

Dynamic Brake Unit, as sown in the following diagram.

DU

DV

DW

DB

24

DB
ON

184 (7.24)

187 (7.36)

259 (10.2)

75 (2.95)

124 (4.88)

73

(2.87)

7.5

(0.30)

475 (18.7)

490 (20.0)

Units: mm (inches)
Approx. mass: 7.0 kg (15.4 lb)

Power line insertion hole
(

φ33 (φ1.30), with rubber bushing)

M4 main
circuit terminals

M3.5 control
circuit terminals

Four, M5 mounting holes

DV

DU

DW

DV

DU

DW

SGDH SERVOPACK