6 Using the Digital Operator

6.2.10 Manual Zero Adjustment and Gain Adjustment of Analog Monitor Output

6-48

Using the Panel Operator

1. Press the MODE/SET Key to select the auxiliary function mode.

2. Press the Up or Down Cursor Key to select the parameter Fn00D.

3. Press the DATA/SHIFT Key for a minimum of one second. The following display will

appear.

4. Press the MODE/SET Key, and the monitor output for the two channels will be dis-

played alternately as shown below.

5. Press the DATA/SHIFT Key for less than one second, and the analog monitor gain con-

stant will be displayed. Pressing the DATA/SHIFT Key again for less than one second
will return to the display shown in the above step 3. or 4.

6. Press the Up or Down Cursor Key to adjust the gain for the analog monitor output.

7. When the gain adjustment has been completed for the two channels, press the DATA/

SHIFT Key for a minimum of one second to return to the auxiliary function mode dis-
play.

This completes the manual gain adjustment of the analog monitor output.

MODE/SET

DATE/

Displayed
alternately

MODE/SET Key

DATA/SHIFT Key

Displayed
alternately

Data Display

Data Setting Change