4 Parameter Settings and Functions

4.2.7 Using Torque Control

4-42

Speed Reference Inputs

Refer to 4.2.1 Speed Reference.

Using the /P-CON Signal

The function of the input signal /P-CON varies with the setting at Pn000.1.

The /P-CON signal function switches automatically when Pn50A.0 is set to 0.

→ Input /P-CON CN1-41

Proportional Control, etc.

Speed/Torque
Control,
Position Control

Pn000.1 Setting

/P-CON Function

0, 1

Switches between P (proportional) and PI (proportional-integral) control.

2

Not used.

3, 4, 5, 6

Switches the direction of rotation in Contact Input Speed Control Mode.

7, 8, 9

Switches the control mode.

A

Turns ON/OFF zero clamp.

B

Turns inhibit ON/OFF.

SERVOPACK

(Pn000.1)

P and PI control switching

Zero clamp ON/OFF switching

Inhibit ON/OFF switching

Control mode switching

Direction of rotation switching

/P-CON