6 operation in parameter setting mode – Yaskawa Large Capacity Sigma II Series User Manual
Page 229

6.1 Basic Operation
6-9
6
6.1.6 Operation in Parameter Setting Mode
Functions can be selected or adjusted by setting parameters. There are two types of parame-
ters. One type requires value setting and the other requires function selection. These two
types use different setting methods.
With value setting, a parameter is set to a value within the specified range of the parameter.
With function selection, the functions allocated to each digit of the seven-segment LED
panel indicator (five digits) can be selected. Refer to Appendix A List of Parameters.
Changing Parameter Settings
The parameter settings can be used for changing parameter data. Check the permitted range
of the parameters in Appendix A List of Parameters, before changing the data.
The example below shows how to change parameter Pn507 from 100 to 85.
Using the Hand-held Digital Operator
1. Press DSPL/SET Key to select the parameter setting mode.
2. Select the parameter number to be set. (Pn507 is selected in this example.)
Press the Left or Right Cursor Key to select the digit. The selected digit will flash.
Press the Up or Down Cursor Key to change the value.
3. Press the DATA/ENTER Key to display the current data for the parameter selected at
step 2.
4. Change to the required data.
Press the Left or Right Cursor Key to select the digit. The selected digit will flash.
Press the Up or Down Cursor Key to change the value.
Continue pressing the key until “00085” is displayed.
5. Press the DATA/ENTER Key to store the data. The display will flash.
6. Press the DATA/ENTER Key once more to return to the parameter number display.
This has changed the setting of the parameter Pn507 from 100 to 85.