1. Press the MODE/SET Key to select the auxiliary function mode.

2. Press the Up or Down Cursor Key to select the parameter Fn011.

3. Press the DATA/SHIFT Key for a minimum of one second to display the servomotor

model and voltage code.

4. Press the MODE/SET Key to display servomotor capacity.

5. Press the MODE/SET Key to display the encoder type and resolution code.

Voltage

Servomotor Model

Code

Voltage

Code

Servomotor Model

00

100 VAC or 140 VDC

00

SGMAH

01

200 VAC or 280 VDC

01

SGMPH

02

400 VAC or 560 VDC

02

SGMSH

03

SGMGH-†A (1500 min

-1

)

04

SGMGH-†B (1000 min

-1

)

05

SGMDH

06

SGMUH

0B

SGMBH

Encoder Type

Encoder Resolution

Code

Type

Code

Resolution

00

Incremental encoder

13

13 bits

01

Absolute encoder

16

16 bits

17

17 bits

20

20 bits

MODE/SET

DATE/

Servomotor model

Voltage

Capacity: Displayed value

× 10 (W)

In this example, the capacity is 100 W.

Encoder type

Encoder resolution