6.1.3 Resetting Servo Alarms

6-4

6.1.3 Resetting Servo Alarms

Servo alarms can be reset using the Digital Operator.

„

Using the Hand-held Digital Operator

Press the RESET Key in status display mode.

„

Using the Built-in Panel Operator

Press the Up and Down Cursor Keys together in status display mode.

The alarm can be reset with CN1-44, or /ALM-RST signal input. Refer to 4.5.1 Using Servo
Alarm and Alarm Code Outputs
.

The servo alarm need not be reset if the control power supply is turned OFF.

If an alarm is ON, reset the alarm after eliminating the cause of the alarm. Refer to 8.2 Troubleshoot-
ing
.

Key

Name

Function

Up Cursor Key

• Press this key to set parameters or display the

set values of parameters.

• Press the Up Cursor Key to increase the set

value.

• Press the Down Cursor Key to decrease the

set value.

• Press the Up and Down Cursor Keys together

to reset a servo alarm.

Down Cursor Key

MODE/SET Key

Press this key to select the status display mode,
auxiliary function mode, parameter setting
mode, or monitor mode.

DATA/SHIFT Key

• Press this key to set each parameter or display

the set value of each parameter.

• This key is used for selecting the editing

(flashing) digit or data setting.

Built-in
Panel Operator

MODE/SET

DATE/

MODE/SET

DATA/

IMPORTANT