7 Servo Selection and Data Sheets

7.5.14 Dynamic Brake (DB) Unit

7-54

• SGDH-3GDE, 4EDE, 5EDE SERVOPACKs

The dynamic brake contactor and Surge Absorption Unit are built into the Dynamic

Brake Unit. Connect the DU, DV, and DW terminals and the Frame Ground (

) on the

Dynamic Brake Unit, and also connect the terminals DBON and DB24 for dynamic
brake contactor control, as shown in the following diagram.

Using Dynamic Brake Resistors Prepared by the Customer

• SGDH-2BDE, 3ZDE SERVOPACKs

The dynamic brake contactor and Surge Absorption Unit are built into the SERVO-
PACK. Connect the dynamic brake resistors only, as shown in the following diagram.

Note: Connect dynamic brake resistors with the following resistance speci-

fications.
400-V SERVOPACKs: Higher than 0.8

DV

DU

DW

SGDH SERVOPACK

DV

DU

DB0N

DW

DB24

DB0N

DB24

Dynamic Brake Unit

DV

DU

DW

Dynamic Brake
resistors

SGDH SERVOPACK