5 Servo Adjustment

5-36

5.5 Analog Monitor

The analog monitor can observe a variety of signals through analog voltages.

Analog monitor signals must be observed through the CN5 connector using DE9404559 dedi-
cated cable.

Analog monitor signals can be selected with parameters Pn003.0 and Pn003.1.

The following monitor signals can be observed.

Cable Color

Signal Name

Description

White

Analog monitor 1

Torque reference:
1 V/100% rated torque

Red

Analog monitor 2

Motor speed: 1 V/1000 min

-1

Black (two wires)

GND (0 V)

-

Pn003.0

Analog Monitor 1

Factory
Setting:

2

Speed/Torque
Control,
Position Control

Pn003.1

Analog Monitor 2

Factory
Setting:

0

Speed/Torque
Control,
Position Control

Setting in Pn003.0 and

Pn003.1

Contents

Monitor signal

Observation gain

0

Motor speed

1 V/1000 min

-1

1

Speed reference

1 V/1000 min

-1

2

Torque reference

1 V/100% rated torque

3

Position error

0.05 V/1 reference unit

4

Position error

0.05 V/100 reference units

5

Reference pulse speed fre-
quency (converted to min

-1

)

1 V/1000 min

-1

6

Motor speed

1 V/250 min

-1

7

Motor speed

1 V/125 min

-1

8 to E

Reserved monitor signal

-

White

CN5

Black

Black

Red

CN8

BATTERY

Ver.

CHARGE

MODE/SET

YASKAWA

SERVOPACK 400V

SGDH-

DATE/

POWER

CN5