5 Servo Adjustment
5-36
5.5 Analog Monitor
The analog monitor can observe a variety of signals through analog voltages.
Analog monitor signals must be observed through the CN5 connector using DE9404559 dedi-
cated cable.
Analog monitor signals can be selected with parameters Pn003.0 and Pn003.1.
The following monitor signals can be observed.
Cable Color
Signal Name
Description
White
Analog monitor 1
Torque reference:
1 V/100% rated torque
Red
Analog monitor 2
Motor speed: 1 V/1000 min
-1
Black (two wires)
GND (0 V)
-
Pn003.0
Analog Monitor 1
Factory
Setting:
2
Speed/Torque
Control,
Position Control
Pn003.1
Analog Monitor 2
Factory
Setting:
0
Speed/Torque
Control,
Position Control
Setting in Pn003.0 and
Pn003.1
Contents
Monitor signal
Observation gain
0
Motor speed
1 V/1000 min
-1
1
Speed reference
1 V/1000 min
-1
2
Torque reference
1 V/100% rated torque
3
Position error
0.05 V/1 reference unit
4
Position error
0.05 V/100 reference units
5
Reference pulse speed fre-
quency (converted to min
-1
)
1 V/1000 min
-1
6
Motor speed
1 V/250 min
-1
7
Motor speed
1 V/125 min
-1
8 to E
Reserved monitor signal
-