4.2 Settings According to Host Controller

4-31

4

Make sure the electronic gear ratio satisfies the following condition:

The SERVOPACK will not work properly if the electronic gear ratio is outside this range. In this case,
modify the load configuration or reference unit.

6. Set the parameters.

Reduce the electronic gear ratio

to the lower terms so that both A and B are integers

smaller than 65535, then set A and B in the respective parameters.

That is all that is required to set the electronic gear ratio.

Set the electronic gear ratio according to equipment specifications.

Electronic gear ratio

• B = [(Number of encoder pulses)

× 4] × [motor speed]

• A = [Reference units (travel distance per load shaft revolution)]

× [load shaft revolution

speed]

Pn202

Electronic Gear Ratio
(Numerator)

Unit:

None

Setting

Range:

1 to 65535

Factory
Setting:

4

Position Control

Pn203

Electronic Gear Ratio
(Denominator)

Unit:

None

Setting

Range:

1 to 65535

Factory
Setting:

1

Position Control

IMPORTANT

0.01

≤ Electronic gear ratio B

A ≤

100

B

A

----

 

 

B
A

Pn202

Pn203

Electronic Gear
Ratio (Numerator)

Electronic Gear
Ratio (Denominator)

M

Reference
input pulse

SGDH SERVOPACK

SGMBH servomotor

Electronic
gear

B
A

B
A

----

 

 

Pn202
Pn203

----------------

=