beautypg.com

A.73, Display and outputs, Status and remedy for alarm – Yaskawa Large Capacity Sigma II Series User Manual

Page 354

background image

8.2 Troubleshooting

8-15

8

„

A.73

A.73: Dynamic Brake Overload

Display and Outputs

Note: OFF:Output transistor is OFF (alarm state). ON: Output transistor is

ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

ON

ON

ON

OFF

Cause

Remedy

A

The product of the square of rotational
motor speed and the combined moment of
inertia of the motor and load (rotation
energy) exceeds the capacity of the dynamic
brake resistor built into SERVOPACK.

• Lower the rotational speed.
• Lower the load moment of inertia.
• Minimize the use of the dynamic brake.

B

Circuit board (1PWB) defective.

Replace SERVOPACK.

When servo OFF signal
turned ON

A

At power ON

B