beautypg.com

A.c8, Display and outputs, Status and remedy for alarm „ a.c9 – Yaskawa Large Capacity Sigma II Series User Manual

Page 366: Status and remedy for alarm

background image

8.2 Troubleshooting

8-27

8

„

A.C8

A.C8: Absolute Encoder Clear Error and Multiturn Limit Setting Error

Display and Outputs

Note: OFF:Output transistor is OFF (alarm state). ON: Output transistor is

ON.

Status and Remedy for Alarm

„

A.C9

A.C9: Encoder Communications Error

Display and Outputs

Note: OFF:Output transistor is OFF (alarm state). ON: Output transistor is

ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

ON

OFF

ON

OFF

Cause

Remedy

A

Encoder defective.

Replace the servomotor.

B

SERVOPACK defective.

Replace SERVOPACK.

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

ON

OFF

ON

OFF

Cause

Remedy

A

Encoder wiring incorrect or disconnected

Check wiring and connectors at encoder.

B

Encoder defective.

Replace the servomotor.

C

SERVOPACK defective.

Replace SERVOPACK.

At power ON

A, B

When resetting multiturn clear
encoder alarm

A, B

At power ON

A, B, C

During servomotor
operation

A, B, C