AT8404

FASTPATH log messages

Page B - 3

AT8404 CLI Reference Manual

B.2

Utilities

NIM

NIM: Attempted event (x), on USP x.x.x before

phase 3

A component issued an interface event during

the wrong initialization phase

NIM

NIM: incorrect phase for operation

An API call was made during the wrong

initialization phase

NIM

NIM: Component(x) failed on event(x) for

intIfNum(x)

A component responded with a fail indication

for an interface event

NIM

NIM: Timeout event(x), intIfNum(x)

remainingMask = “xxxx”

A component did not respond before the NIM

timeout occurred

Table 3: System Log Messages

Component

Message

Cause

SYSTEM

Configuration file fastpath.cfg size is 0 (zero)

bytes

The configuration file could not be read. This

message may occur on a system for which no

configuration has ever been saved or for

which configuration has been erased.

SYSTEM

could not separate

SYSAPI_CONFIG_FILENAME

The configuration file could not be read. This

message may occur on a system for which no

configuration has ever been saved or for

which configuration has been erased.

SYSTEM

Building defaults for file version

Configuration did not exist or could not be

read for the specified feature or file. Default

configuration values will be used. The file

name and version are indicated.

SYSTEM

File : same version (version num)

but the sizes (->

version size) differ

The configuration file which was loaded was of

a different size than expected for the version

number. This message indicates the

configuration file needed to be migrated to the

version number appropriate for the code

image. This message may appear after

upgrading the code image to a more current

release.

SYSTEM

Migrating config file from version

to

The configuration file identified was migrated

from a previous version number. Both the old

and new version number are specified. This

message may appear after upgrading the

code image to a more current release.

SYSTEM

Building Defaults

Configuration did not exist or could not be

read for the specified feature. Default

configuration values will be used.

SYSTEM

sysapiCfgFileGet failed size =

of file> version =

Configuration did not exist or could not be

read for the specified feature. This message

is usually followed by a message indicating

that default configuration values will be used.

Table 4: Trap Mgr Log Message

Component

Message

Cause

Trap Mgr

Link Up/Down: unit/slot/port

An interface changed link state.

Table 2: NIM Log Messages (Continued)

Component

Message

Cause