beautypg.com

1 configuration, 2 lineconfig, 3 serial baudrate – Kontron AT8404 CLI User Manual

Page 282: 1 no serial baudrate, 4 serial timeout, 1 no serial timeout, Configuration - 6, Lineconfig - 6, Serial baudrate - 6, Serial timeout - 6

background image

Management Commands

AT8404

AT8404 CLI Reference Manual

Page 5 - 6

5.2.1

configuration

This command gives you access to the Global Config mode. From the Global Config mode, you can configure a
variety of system settings, including user accounts. From the Global Config mode, you can enter other command
modes, including Line Config mode.

5.2.2

lineconfig

This command gives you access to the Line Config mode, which allows you to configure various Telnet settings and
the console port.

5.2.3

serial baudrate

This command specifies the communication rate of the terminal interface. The supported rates are 1200, 2400,
4800, 9600, 19200, 38400, 57600, 115200.

5.2.3.1

no serial baudrate

This command sets the communication rate of the terminal interface.

5.2.4

serial timeout

This command specifies the maximum connect time (in minutes) without console activity. A value of 0 indicates that
a console can be connected indefinitely. The time range is 0 to 160.

5.2.4.1

no serial timeout

This command sets the maximum connect time (in minutes) without console activity.

Format

configuration

Mode

Privileged EXEC

Format

lineconfig

Mode

Global Config

Default

9600

Format

serial baudrate {1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 |
115200}

Mode

Line Config

Format

no serial baudrate

Mode

Line Config

Default

5

Format

serial timeout <0-160>

Mode

Line Config

Format

no serial timeout

Mode

Line Config