beautypg.com

1 no sflow poller, 4 show sflow agent, Show sflow agent - 61 – Kontron AT8404 CLI User Manual

Page 275: At8404 utility commands

background image

AT8404

Utility Commands

Page 4 - 61

AT8404 CLI Reference Manual

4.13.3.1

no sflow poller

Use this command to reset the sFlow poller instance to the default settings.

4.13.4

show sflow agent

The sFlow agent collects time-based sampling of network interface statistics and flow-based samples. These are
sent to the configured sFlow receivers. Use this command to display the sFlow agent information.

Example: The following shows example CLI display output for the command.

(switch) #show sflow agent

sFlow Version.................................. 1.3;Broadcom Corp;1.0
IP Address..................................... 10.131.12.66

show sflow pollers

Use this command to display the sFlow polling instances created on the switch. Use “-” for range.

Poll Interval

Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter sampling.

When set to zero (0), all the poller parameters are set to their corresponding default value.

The range is 0-86400. The default is 0. A value of N means once in N seconds a counter

sample is generated.

Format

no sflow poller { | interval }

Mode

Interface Config

Format

show sflow agent

Mode

Privileged EXEC

Field

Description

sFlow Version

Uniquely identifies the version and implementation of this MIB. The version string must have

the following structure: MIB Version; Organization; Software Revision where:
MIB Version: ‘1.3’, the version of this MIB.
Organization: Broadcom Corp.
Revision: 1.0

IP Address

The IP address associated with this agent.

Format

show sflow pollers

Mode

Privileged EXEC

Field

Description

Poller Data Source The sFlowDataSource (slot/port) for this sFlow sampler. This agent will support Physical ports

only.

Receiver Index

The sFlowReceiver associated with this sFlow counter poller.

Poller Interval

The number of seconds between successive samples of the counters associated with this

data source.

Field

Description