Rockwell Automation 592- E300 Overload Relay User Manual User Manual
Page 338
338
Rockwell Automation Publication 193-UM015B-EN-P - November 2013
Appendix B Parameter List
Energy
Monitoring
(Continued)
95
kVARhNet10E9
Total Reactive Energy Net
(kVARh) Word 10^9
INT
2
1
-999
999
0
96
kVARhNet10E6
Total Reactive Energy Net
(kVARh) Word 10^6
INT
2
1
-999
999
0
97
kVARhNet10E3
Total Reactive Energy Net
(kVARh) Word 10^3
INT
2
1
-999
999
0
98
kVARh Net 10E0
Total Reactive Energy Net
(kVARh) Word 10^0
INT
2
1
-999
999
0
99
kVARhNet10E-3
Total Reactive Energy Net
(kVARh) Word 10^-3
INT
2
1
-999
999
0
100
kVAhTimes10E9
Total Apparent Energy (kVAh)
Word 10^9
INT
2
1
-999
999
0
101
kVAhTimes10E6
Total Apparent Energy (kVAh)
Word 10^6
INT
2
1
-999
999
0
102
kVAhTimes10E3
Total Apparent Energy (kVAh)
Word 10^3
INT
2
1
-999
999
0
103
kVAhTimes10E0
Total Apparent Energy (kVAh)
Word 10^0
INT
2
1
-999
999
0
104
kVAhTimes10E-3
Total Apparent Energy (kVAh)
Word 10^-3
INT
2
1
-999
999
0
105
kWDemand
Real Power Demand
DINT
4
1000
-2000000000 2000000000 0
kW
106
MaxkWDemand
Maximum Real Power Demand
DINT
4
1000
-2000000000 2000000000 0
kW
107
VARDemand
Reactive Power Demand
DINT
4
1000
-2000000000 2000000000 0
kVAR
108
MaxVARDemand
Maximum Reactive Demand
DINT
4
1000
-2000000000 2000000000 0
kVAR
109
VADemand
Apparent Power Demand
DINT
4
1000
0
2000000000 0
kVA
110
MaxVADemand
Maximum Apparent Power
Demand
DINT
4
1000
0
2000000000 0
kVA
Analog
Monitoring
111
InAnMod1Ch00
Value measured at Analog
Expansion Module 1 Input 00
UINT
2
1
0
65535
0
112
InAnMod1Ch01
Value measured at Analog
Expansion Module 1 Input 01
UINT
2
1
0
65535
0
113
InAnMod1Ch02
Value measured at Analog
Expansion Module 1 Input 02
UINT
2
1
0
65535
0
114
InAnMod2Ch00
Value measured at Analog
Expansion Module 2 Input 00
UINT
2
1
0
65535
0
115
InAnMod2Ch01
Value measured at Analog
Expansion Module 2 Input 01
UINT
2
1
0
65535
0
116
InAnMod2Ch02
Value measured at Analog
Expansion Module 2 Input 02
UINT
2
1
0
65535
0
117
InAnMod3Ch00
Value measured at Analog
Expansion Module 3 Input 00
UINT
2
1
0
65535
0
118
InAnMod3Ch01
Value measured at Analog
Expansion Module 3 Input 01
UINT
2
1
0
65535
0
119
InAnMod3Ch02
Value measured at Analog
Expansion Module 3 Input 02
UINT
2
1
0
65535
0
120
InAnMod4Ch00
Value measured at Analog
Expansion Module 4 Input 00
UINT
2
1
0
65535
0
121
InAnMod4Ch01
Value measured at Analog
Expansion Module 4 Input 01
UINT
2
1
0
65535
0
122
InAnMod4Ch02
Value measured at Analog
Expansion Module 4 Input 02
UINT
2
1
0
65535
0
Group
Param
No.
Parameter Name
Description
Type
Data Size
(bytes)
Scale
Factor
Min
Max
Default Units