Commands Chapter 6

Clear Command

Clear Command (Parameter 165) allows the user to clear historical logs,
operating statistics, and energy data within the non-volatile memory of the E300
Electronic Overload Relay.

274

L3UCWarningLevel

40

%

403

UVATripDelay

1.0

Sec

524

InAMod3C2TripLvl

0

275

OCInhibitTime

10

Sec

404

UVATripLevel

0.000

kVA

525

InAMod3C2WarnLvl

0

276

L1OCTripDelay

1.0

Sec

405

UVAWarningLevel

0.000

kVA

526

OutAnMod3Type

Disable

277

L1OCTripLevel

100

%

406

OVAInhibitTime

10

Sec

527

OutAnMod3Select

Ave %FLA

278

L1OCWarningLevel

90

%

407

OVATripDelay

1.0

Sec

528

OutAnMod3FltActn

Zero

279

L2OCTripDelay

1.0

Sec

408

OVATripLevel

0.000

kVA

529

OutAnMod3dlActn

Zero

280

L2OCTripLevel

100

%

409

OVAWarningLevel

0.000

kVA

530

InAnMod4Ch00Type Disable

281

L2OCWarningLevel

90

%

410

UPFLagInhibTime

10

Sec

531

InAMod4Ch0Format

Eng Units

282

L3OCTripDelay

1.0

Sec

411

UPFLagTripDelay

1.0

Sec

532

InAMod3C0TmpUnit

Degrees C

283

L3OCTripLevel

100

%

412

UPFLagTripLevel

-90

%

533

InAMod4C0FiltFrq

17 Hz

284

L3OCWarningLevel

90

%

413

UPFLagWarnLevel

-95

%

534

InAMod4C0OpCktSt Upscale

285

LineLossInhTime

10

Sec

414

OPFLagInhibTime

10

Sec

535

InAnMod4Ch0RTDEn

3-Wire

286

L1LossTripDelay

1.0

Sec

415

OPFLagTripDelay

1.0

Sec

536

InAMod4C0TripDly

1.0

Sec

287

L2LossTripDelay

1.0

Sec

416

OPFLagTripLevel

-95

%

537

InAMod4C0TripLvl

0

288

L3LossTripDelay

1.0

Sec

417

OPFLagWarnLevel

-90

%

538

InAMod4C0WarnLvl

0

291

Datalink0

0

418

UPFLeadInhibTime

10

Sec

539

InAnMod4Ch01Type

Disable

292

Datalink1

0

419

UPFLeadTripDelay

1.0

Sec

540

InAMod4Ch1Format

Eng Units

293

Datalink2

0

420

UPFLeadTripLevel

90

%

541

InAMod4C1TmpUnit

Degrees C

294

Datalink3

0

421

UPFLeadWarnLevel

95

%

542

InAMod4C1FiltFrq

17 Hz

295

Datalink4

0

422

OPFLeadInhibTime

10

Sec

543

InAMod4C1OpCktSt

Upscale

296

Datalink5

0

423

OPFLeadTripDelay

1.0

Sec

544

InAnMod4Ch1RTDEn

3-Wire

297

Datalink6

0

424

OPFLeadTripLevel

95

%

545

InAMod4C1TripDly

1.0

Sec

298

Datalink7

0

425

OPFLeadWarnLevel

90

%

546

InAMod4C1TripLvl

0

426

DemandPeriod

15

Min

547

InAMod4C1WarnLvl

0

427

NumberOfPeriods

1

548

InAnMod4Ch02Type

Disable

549

InAMod4Ch2Format

Eng Units

550

InAMod4C2TmpUnit

Degrees C

551

InAMod4C2FiltFrq

17 Hz

552

InAMod4C2OpCktSt

Upscale

553

InAnMod4Ch2RTDEn 3-Wire

554

InAMod4C2TripDly

1.0

Sec

555

InAMod4C2TripLvl

0

556

InAMod4C2WarnLvl

0

557

OutAnMod4Type

Disable

558

OutAnMod4Select

Ave %FLA

559

OutAnMod4FltActn

Zero

560

OutAnMod4dlActn

Zero

Number Parameter Name

Default
Value

Units

Number Parameter Name

Default
Value

Units

Number

Parameter Name

Default
Value

Units