beautypg.com

1 a/d control status register (high) (adcs1), A/d control status register (high) (adcs1) – FUJITSU F2MCTM-16LX User Manual

Page 362

background image

346

CHAPTER 18 8-/10-BIT A/D CONVERTER

18.3.1

A/D Control Status Register (High) (ADCS1)

The A/D control status register (High) (ADCS1) provides the following settings:
• Starting A/D conversion function by software
• Selecting start trigger for A/D conversion
• Storing A/D conversion results in A/D data register to enable or disable interrupt

request

• Storing A/D conversion results in A/D data register to check and clear interrupt

request flag

• Pausing A/D conversion and checking state during conversion

A/D Control Status Register (High) (ADCS1)

Figure 18.3-2 A/D Control Status Register (High) (ADCS1)

Reset value

0000000X

B

12

13

11

10

9

8

bit8

14

15

STRT

0

1

Not starting A/D conversion function

Starting A/D conversion function

A/D conversion software starting bit

bit9

Read value is always 1.

Undefined bit

STS1

0

0

1

1

Starting software

Starting software or external trigger

Starting software

Starting software or external trigger

A/D conversion starting trigger select bit

bit11

0

1

PAUS

Suspended flag bit

(This bit is enabled only when EI

2

OS is used.)

bit12

INTE

0

1

Interrupt request disable

Interrupt request enable

Interrupt request enable bit

bit13

W

R/W

R/W

R/W

R/W

R/W

R/W

STS0

0

1

0

1

bit10

0

1

INT

A/D conversion not terminated

A/D conversion terminated

Clear to "0"

No effect

Interrupt request flag bit

Read

Write

Read

Write

bit14

0

1

BUSY

A/D conversion terminated
(inactive state)

A/D conversion in operation

Terminates A/D conversion
forcibly

No effect

A/D conversion-on flag bit

bit15

BUSY INT INTE PAUS STS1 STS0 STRT


-

Address

000069

H

Read

Write

Conversion is not suspended.

Conversion is suspended.

Clear to "0".

No effect.

X

W

R/W : Read/Write

: Write only

: Reset value

: Undefined bit
: Indeterminate