beautypg.com

Operation modes of 8-/16-bit ppg timer – FUJITSU F2MCTM-16LX User Manual

Page 299

background image

283

CHAPTER 16 8-/16-BIT PPG TIMER

Operation Modes of 8-/16-bit PPG Timer

8-bit PPG output 2-channel independent operation mode

The 8-bit PPG output 2-channel independent operation mode causes the 2-channel modules (PPGC and

PPGD) to operate as each independent 8-bit PPG timer.

Table 16.1-1 shows the interval times in the 8-bit PPG output 2-channel independent operation mode.

16-bit PPG output operation mode

The 16-bit PPG output operation mode concatenates the 2-channel modules (PPGC and PPGD) to operate

as a 16-bit 1-channel PPG timer.

Table 16.1-2 shows the interval times in this mode.

Table 16.1-1 Interval Times in 8-bit PPG Output 2-channel Independent Operation Mode

Count Clock Cycle

PPGC, PPGD

Interval Time

Output Pulse Time

1/

φ(41.7 ns)

1/

φ to 2

8

/

φ

2/

φ to 2

9

/

φ

2/

φ(83.3 ns)

2/

φ to 2

9

/

φ

2

2

/

φ to 2

10

/

φ

2

2

/

φ(167 ns)

2

2

/

φ to 2

10

/

φ

2

3

/

φ to 2

11

/

φ

2

3

/

φ(333 ns)

2

3

/

φ to 2

11

/

φ

2

4

/

φ to 2

12

/

φ

2

4

/

φ(667 ns)

2

4

/

φ to 2

12

/

φ

2

5

/

φ to 2

13

/

φ

2

9

/HCLK(128

µs)

2

9

/HCLK to 2

17

/HCLK

2

10

/HCLK to 2

18

/HCLK

HCLK: Oscillation clock
φ : Machine clock
The parenthesized values are provided when the oscillation clock operates at 4 MHz and the machine clock operates
at 24 MHz.

Table 16.1-2 Interval Times in 16-bit PPG Output Operation Mode

Count clock cycle

Interval time

Output pulse time

1/

φ(41.7 ns)

1/

φ to 2

16

/

φ

2/

φ to 2

17

/

φ

2/

φ(83.3 ns)

2/

φ to 2

17

/

φ

2

2

/

φ to 2

18

/

φ

2

2

/

φ(167 ns)

2

2

/

φ to 2

18

/

φ

2

3

/

φ to 2

19

/

φ

2

3

/

φ(333 ns)

2

3

/

φ to 2

19

/

φ

2

4

/

φ to 2

20

/

φ

2

4

/

φ(667 ns)

2

4

/

φ to 2

20

/

φ

2

5

/

φ to 2

21

/

φ

2

9

/HCLK(128

µs)

2

9

/HCLK to 2

25

/HCLK

2

10

/HCLK to 2

26

/HCLK

HCLK: Oscillation clock
φ : Machine clock
The parenthesized values are provided when the oscillation clock operates at 4 MHz and the machine clock operates
at 24 MHz.