112

CHAPTER 6 CLOCK SUPERVISOR

Main clock supervisor

The oscillation of the main oscillation clock (HCLK) is supervised by using the clock from the

CR oscillation circuit as a clock source.

Sub clock supervisor

The oscillation of the sub oscillation clock (SCLK) is supervised by using the clock from the

CR oscillation circuit as a clock source.

Control circuit

Disable or enable for main/sub clock supervisor, existence of internal reset generation when

clock halt condition is detected, and switching to CR oscillation clock of clock to be monitored

are controlled by setting of clock supervisor control register (CKSCR).

Clock supervisor control register (CKSCR)

Disable or enable for main/sub clock supervisor, existence of internal reset generation when

clock halt condition is detected, or switching to CR oscillation clock of clock to be monitored

are selected.

Main clock selector

CR oscillation clock is outputted as main clock when the main oscillation clock is missing.

Sub clock selector

The divided clock of CR oscillation clock is outputted as sub clock when the sub oscillation

clock is missing.

CR oscillation circuit

Internal CR oscillation clock circuit. Disable/enable the CR oscillation can be selected by the