beautypg.com

FUJITSU F2MCTM-16LX User Manual

Page 121

background image

105

CHAPTER 5 CLOCKS

Figure 5.5-1 shows the status change caused by machine clock switching.

Figure 5.5-1 Status Change Diagram for Machine Clock Selection

Main
MCS = 1
MCM = 1
SCS = 1
SCM = 1
CS1, CS0 = xx

B

CS2=x

PLL1 --> Main
MCS = 1
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 00

B

CS2=0

PLL1: Multiplied
MCS = 0
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 00

B

CS2=0

PLL2: Multiplied
MCS = 0
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 01

B

CS2=0

PLL3: Multiplied
MCS = 0
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 10

B

CS2=0

PLL4: Multiplied
MCS = 0
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 11

B

CS2=0

PLL2 --> Main
MCS = 1
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 01

B

CS2=0

PLL3 --> Main
MCS = 1
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 10

B

CS2=0

PLL4 --> Main
MCS = 1
MCM = 0
SCS = 1
SCM= 1
CS1, CS0 = 11

B

CS2=0

PLL1 --> Sub
MCS = 1
MCM = 0
SCS = 0
SCM = 1
CS1, CS = 00

B

CS2=0

PLL2 --> Sub
MCS = 1
MCM = 0
SCS = 0
SCM = 1
CS1, CS0 = 01

B

CS2=0

PLL3 --> Sub
MCS = 1
MCM = 0
SCS = 0
SCM = 1
CS1, CS0 =10

B

CS2=0

PLL4 --> Sub
MCS = 1
MCM = 0
SCS = 0
SCM = 1
CS1, CS0 = 11

B

CS2=0

(10)

Main --> Sub
MCS = 1
MCM = 1
SCS = 0
SCM = 1
CS1, CS0 = xx

B

CS2=x

Sub --> Main
MCS = 1
MCM = 1
SCS = 1
SCM = 0
CS1, CS0 = xx

B

CS2=x

Sub
MCS = X
MCM = 1
SCS = 0
SCM = 0
CS1, CS0 = xx

B

CS2=x

Main --> PLLx
MCS = 0
MCM = 1
SCS = 1
SCM = 1
CS1, CS0 = xx

B

CS2=x

(21)

(21)

(21)

(21)

(21)

(11)

(10)

(1)

(12)

(13)

(8)

(2)

(3)

(4)

(6)

(5)

PLL6: Multiplied
MCS = 0
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 10

B

CS2=1

PLL6 --> Main
MCS = 1
MCM = 0
SCS = 1
SCM = 1
CS1, CS0 = 10

B

CS2=1

PLL6 --> Sub
MCS = 1
MCM = 0
SCS = 0
SCM = 1
CS1, CS0 =10

B

CS2=1

(8)

(9)

(10)

(8)

(9)

(10)

(8)

(9)

(10)

(8)

(9)

(10)

(8)

(9)

(10)

(12)

(14)
(15)

(16)
(17)

(18)

Sub --> PLL
MCS = 0
MCM = 1
SCS = 1
SCM = 0
CS1, CS0 = xx

B

CS2=0

(11)

(20)