beautypg.com

Loading e-mems – Grass Valley Kalypso User Manual V.15.0 User Manual

Page 170

background image

170

Kalypso — User Manual

Section 3 — System Operation

3.

Touch the

Enter Reg(s)

button, then touch the Register(s) data pad. A

keypad appears allowing the entry of a range of registers or banks
(

Figure 140

).

Figure 140. File Operations Range Entry Window

4.

Be sure to select the correct Entry Mode, either

Register

or

Bank

, on the

lower left.

5.

Enter the desired range of registers or banks on the keypad, using the

Next

and/or

Thru

buttons, then touch

Enter

.

6.

Touch

Save

. The range displayed in the Registers data pad will be saved

to the target location.

Loading E-MEMs

E-MEMs are loaded using the same methods as above, by touching the

Load

button instead of Save.

CAUTION The Load button immediately replaces existing E-MEM register data with the

new E-MEM data. While this does not directly affect the work buffer, as soon
as the register runs to the next keyframe or is recalled the work buffer will
reflect the new data, and so can change the Kalypso system program output
signals.