Section 40.2.15, Section 40.2.16 – Westermo RedFox Series User Manual
Page 941

Westermo OS Management Guide
Version 4.17.0-0
Usage Set redirect broadcast, i.e., redirect all Modbus broadcasts to Modbus
address 1.
Only applicable when configuring the Modbus Gateway in ”server” mode
(see
Default values Disabled
Error messages None defined yet.
40.2.15
Setting Request Queue
Syntax [no] request-queue
Context modbus context (server mode only)
Usage Enabled/disables Request Queue.
Only applicable when configuring the Modbus Gateway in ”server” mode
(see
Default values Enabled
Error messages None defined yet.
40.2.16
Setting Exceptions
Syntax [no] exceptions [ignore-unknown]
Context modbus context
Usage Enable/disables handling of Modbus exceptions. With Modbus Exceptions
enabled, the Modbus Gateway will react upon and respond to certain er-
ror conditions, e.g., if a Gateway in client mode receives a (serial) Modbus
message addressed to Modbus unit not found in its Map table. If excep-
tion handling is desired, except for this particular situation, the gateway
can be configured to ignore exceptions for unknown units (”exceptions
ignore-unknown”).
Use ”no exceptions” to disable exception handling.
Default values Enabled (all exceptions enabled)
Error messages None defined yet.