(remote) Server.
In Peer mode, it is possible to specify one or more destinations/peers
(maximum 32), and the address can be IP unicast, broadcast
, or mul-
ticast
Default: Disabled
– Dynamic peer: Peer mode only. When dynamic peer
is enabled, data
will be sent to the source of the latest incoming data. (Until there is
incoming data, the unit will send data to the (first) configured destina-
tion/peer.)
Default: Disabled
❼ DTR Control: The DTR (Data Terminal Ready) Control setting is only appli-
cable for RS-232 serial ports, and when Serial Over IP is configured in TCP
Server or TCP Client mode. With DTR Control enabled, the activation of the
TCP session is controlled by the status of the DTR control line:
– TCP Server: With Serial Over IP in TCP server mode, the server will
await activation of DTR before it accepts remote TCP clients to establish
a connection.
– TCP Client: With Serial Over IP in TCP client mode, the client will not
make any TCP connection attempts as long as the DTR is inactive.
– AT Command: With Serial Over IP in AT Command mode, an active con-
nection will be closed if the DTR signal is dropped. When establishing
connections the DTR signal is ignored.
With DTR Control enabled, both TCP clients and servers will close an es-
tablished connection if the DTR becomes inactive. Furthermore, with DTR
Control enabled, data arriving on the serial port will be dropped while DTR
is inactive.
Default: Disabled
5
Sending to the data link IP broadcast (255.255.255.255) will only work if the unit has a default
gateway configured (see
). IP subnet broadcast (e.g., 192.168.1.255) is preferred.
6
Sending data to a multicast address will only work if the unit has a default gateway configured
(see
7
The ”dynamic peer” setting is referred to as ”latest calling” in Westermo EDW-100.
902