Section 7.3.23 – Westermo RedFox Series User Manual
Page 146

Westermo OS Management Guide
Version 4.17.0-0
itself or factory-config, which is read-only. Hence we recommend using:
”copy console config
Default values N/A
Examples
1. Restore factory default (to running configuration)
Example
example:/#> copy factory-config running-config
Using default factory.cfg found in firmware image.
Stopping Syslog daemon ..................................... [ OK ]
Starting Syslog daemon ..................................... [ OK ]
example:/#>
2. Store running configuration to startup configuration
Example
example:/#> copy running-config startup-config
example:/#>
3. Copy configuration file from USB to local configuration file config3.
Example
example:/#> copy usb://myconfig.cfg config3
Copying myconfig.cfg to config3 ...
Done.
example:/#>
4. Copy configuration file onto remote server using FTP.
Example
example:/#> copy cfg://config0.cfg ftp://mylogin:[email protected]/myconfig
example:/#>
7.3.23
Delete a Configuration File
Syntax erase [filesys://]
filesys can be ”cfg”, ”log”, or ”usb”, with ”cfg” as default.
Context