Section 39.3.8, Section 39.3.9, Section 39.3.10 – Westermo RedFox Series User Manual
Page 918

Westermo OS Management Guide
Version 4.17.0-0
39.3.8
Setting Protocol Extensions
Syntax [no] protocol
Context seroip context
Usage Set protocol extensions. This is only applicable in server mode (
When accessing the serial port with Westermo’s OEM version of Serial/IP
the protocol extension setting should be ”protocol telnet”.
Use ”no protocol” (or ”protocol raw”) to disable protocol extensions.
Default values Disabled (”no protocol”)
Error messages None defined yet.
39.3.9
Setting secondary listen port
Syntax [no] listen-secondary port
Context seroip context
Usage Additional local TCP port to listen to. Will listen on the same interface as
set in Listen option.Only applicable in TCP-Server mode.
Default values Disabled (”no listen-secondary”).
Error messages None defined yet.
39.3.10
Setting secondary mode
Syntax [no] secondary-mode
Context seroip context
Usage How to handle concurrent access to serial port. See
for
available modes.Only applicable in TCP-Server mode.
Default values Slotted, timeout 600 ms (”no secondary-mode”).
Error messages None defined yet.
8
Serial/IP is a registered trademark of Tactical Software LLC.
918
➞ 2015 Westermo Teleindustri AB