Westermo RedFox Series User Manual
Page 550

Westermo OS Management Guide
Version 4.17.0-0
Continued from previous page
Enabled
To enable the trigger - check the box, to disable un-
check the box.
Severity Active
Severity level when active
Severity Inactive
Severity level when inactive
Condition
Controls the condition for triggering (High/low)
Sensors
The sensor source for this trigger
Threshold Rising
The Rising threshold is the higher threshold value for
the sensor. When the current sample value is higher
than this value, and the last sample was lower than
this value, an action is triggered. Valid for none binary
sensors such as temperature and SNR.
Threshold Falling
The falling threshold is the lower threshold value for
the sensor. When the current sample value is less than
this value, and the last sample was greater than this
value, an action is triggered. Valid for none binary sen-
sors such as temperature and SNR.
Action
Selects the action for the trigger
Port
The ports on your switch is grouped as on the actual
hardware, in slots. To get alarms for a a specific port,
check the check-box located underneath the port label.
In the picture above you see ports 1/1, 1/2 and 2/1 are
marked as alarm sources for this link alarm trigger.
550
➞ 2015 Westermo Teleindustri AB