beautypg.com

3 managing shdsl ports via the cli, Shdsl port configuration, Section 10.3.1 – Westermo RedFox Series User Manual

Page 218: Shdsl port con, Figuration

background image

Westermo OS Management Guide

Version 4.17.0-0

10.3

Managing SHDSL ports via the CLI

The table below shows SHDSL port management features available via the CLI.

Command

Default

Section

Configure SHDSL port settings
port [dsl|shdsl|. . . ]

Section 10.3.1

[no] co

Section 10.3.2

[no] speed

Auto

Section 10.3.3

[no] noise-margin

Normal

Section 10.3.4

[no] ghs-threshold

Disabled

Section 10.3.5

[no] paf

Disabled

Section 10.3.6

[no] low-jitter

Disabled

Section 10.3.7

[no] emf

Enabled

Section 10.3.8

Port settings in common with Ethernet ports (

chapter 8

)

[no] enable

Enabled

Section 8.3.3

[no] priority <0-7>

0

Section 8.3.6

[no] priority-mode

tag

Section 8.3.7

[no] link-alarm

Disabled

Section 8.3.8

[no] rate-limit <70-2560>

Disabled

Section 8.3.9

[no] traffic-shaping <70-2560>

Disabled

Section 8.3.10

[no] default-vid

Disabled

Section 8.3.14

Show SHDSL related status and statistics
show

Section 10.3.9

show ports

Section 8.3.15

show rmon

Section 9.3

10.3.1

Managing SHDSL port settings

Syntax port [dsl|shdsl|...]

Context

Global Configuration

context

218

➞ 2015 Westermo Teleindustri AB