24.3.6
Configure Alarm Condition Setting
Syntax condition
Alternate keywords are possible:
❼ rising and up are equivalents to high.
❼ falling and down are equivalents to low.
Context
context
Usage Define whether the high or low trigger state should be considered the
alarm state, while the other is considered the normal state.
Some triggers, such as link-alarm and power triggers have a static (prede-
fined) alarm condition setting. (Both link-alarm and power triggers have
condition set to low). For other triggers, the alarm condition setting is con-
figurable.
See
for more information.
Use ”show condition” to show the alarm condition setting for this trigger.
Default values Differs for different trigger types
24.3.7
Configure Rising and Falling Thresholds
Syntax threshold
Context
context
Usage Set falling and rising thresholds. The thresholds may be set to the same
value, but by using different thresholds (rising higher than falling) one can
avoid receiving multiple events when the alarm source fluctuates around
the alarm threshold.
Triggers which are binary to their nature, such as link-alarm, power, and
digital-in triggers have implicit thresholds, which cannot be configured.
See
for more information.
Use command ”show threshold” to show the trigger threshold setting (both
rising and falling thresholds) for this trigger.
Default values rising 0 and falling 0 (except for binary alarm sources)