Section 10.3.2, Section 10.3.3 – Westermo RedFox Series User Manual
Page 219

Westermo OS Management Guide
Version 4.17.0-0
Usage Enter the
context.
A ”PORTLIST” is a comma separated list of ranges of SHDSL ports without
intermediate spaces, e.g., ”1/1,1/2” on a slotted product, or ”1-3,5” on a
non-slotted product.
The port qualifier keyword ”shdsl” (or ”dsl”) is not needed if the numbers
in the ”PORTLIST” are unique to DSL ports.
For a more general description of the ”port” command, see
Use ”show port [dsl|shdsl] [
formation of the given PORT or PORTLIST. Alternatively, the command ”show”
can be run within the
context, to show the config-
uration of a port (or list of ports).
Default values Not applicable.
10.3.2
Setting SHDSL port mode (CO/CPE)
Syntax [no] co
Context
context
Usage Set the SHDSL port to operate in central office (CO) or customer premises
equipment (CPE) mode.
When connecting switches via SHDSL it is important that one side puts its
SHDSL port in CO mode (”co”) while the other side puts its SHDSL port in
CPE mode (”no co”).
Default values Factory default for DDW-225/226 is to have port 1/1 in CPE mode
(”no co”), and port 1/2 in CO mode (”co”). Factory default for DDW-142
(and DDW-142-485) is to have port DSL 1 in CPE mode (”no co”), and port
DSL2 in CO mode (”co”).
Use ”show co” to show whether the SHDSL port is configured to operate as
Central Office or Customer Premises Equipment.
10.3.3
Setting SHDSL port rate
Syntax [no] speed
Context
context
➞ 2015 Westermo Teleindustri AB
219