Section 38.3.3, Section 38.3.4, Section 38.3.5 – Westermo RedFox Series User Manual
Page 890

Westermo OS Management Guide
Version 4.17.0-0
38.3.3
Setting number of data bits
Syntax [no] databits <7-8>
Context
context
Usage Set the number number of data bits.
Use ”no databits” to reset the number of data bits to the default setting.
Use ”show databits” to show the configured number of databits for this
serial port.
Default value 8
38.3.4
Setting parity error detection
Syntax [no] parity
Context
context
Usage Set parity error detection. Use command ”parity odd” to specify odd
parity, or ”parity even” to specify even parity on this serial port.
Use ”no parity” to disable parity checking on this port.
Use ”show parity” to show the parity checking setting for this port: None
(i.e., Disabled), Odd, or Even.
Default value Disabled (no parity).
38.3.5
Setting number of stop bits
Syntax [no] stopbits <1|2>
Context
context
Usage Set the number number of stop bits (1 or 2).
Use ”no stopbits” reset the number of stop bits to the default setting.
Use ”show stopbits” to show the configured number of stopbits for this
serial port.
Default value 1
890
➞ 2015 Westermo Teleindustri AB