beautypg.com

Westermo RedFox Series User Manual

Page 397

background image

Westermo OS Management Guide

Version 4.17.0-0

the underlying VLAN interface must also be up. See

chapter 33

for more

information on PPP.

GRE interfaces: (only for WeOS Extended) For a GRE interface to get status

up, the GRE interface (and the associated GRE tunnel instance) must be
enabled.

19.2.2

Interface Settings at Factory Default

WeOS products typically have all Ethernet and DSL ports mapped to VLAN 1 by
factory default, and the network interface associated with VLAN 1 is named vlan1.
The exception is Falcon, as described later in this section.hus by factory default,
a WeOS unit has network interfaces vlan1 and lo (logical ”loopback” interface).

The factory default settings for interfaces vlan1 and lo are presented below. Most
of the loopback settings are permanent (non-configurable).

Interface parameters

Factory Default Setting (General)

vlan1

lo

Administrative Mode

Enabled

Enabled

IP address

Dynamic

Static

(DHCP)

127.0.0.1

Netmask

(Dynamic)

255.0.0.0

Secondary IP addresses

192.168.2.200

Disabled

Secondary Netmask

255.255.255.0

N/A

MAC address

Auto

N/A

MTU

Auto (1500)

16436

TCP-MSS

Disabled

Disabled

Admin Distance

1

16

Management Interface

Enabled

1

Disabled

The interface administrative distance and management interface concepts are
described in

sections 19.2.6

and

19.2.7

.

As stated earlier, Falcon has a different factory default settings than other WeOS
products. The Ethernet ports are all mapped to VLAN 1 and interface vlan1 as
usual, but the Falcon xDSL port resides on a separate VLAN (VLAN 1006) and
interface (vlan1006). The factory default settings for the associated interfaces
are shown below. Most of the loopback interface (lo) settings are permanent
(non-configurable).

➞ 2015 Westermo Teleindustri AB