❼ Speed: Set serial port data rate (bits/s).
– Possible data rates for RS-232 (and RS-422/485) are: 50, 75, 110, 134,
150, 200, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bits/s
– Additional data rates for RS-422/485 : 230400, 315000, 460800, 500000,
576000, 615000, 921600, 1000000, 1152000, 1500000, 2000000 bits/s
Default: 115200 bits/s
❼ Data character:
Logical 1
Logical 0
Stop bits
Data bits (7−8)
Start bit
Parity
(opt.)
(1−2)
– Data bits: Number of data bits per character. Possible values are 7-8
bits. Default: 8 data bits
– Parity: Parity error detection setting. Possible settings are none (no
parity checking), even and odd parity checking. When configured to
use even (or odd) parity, an additional bit (the parity bit) is transmitted
after the data bits to enforce that an even (or odd, respectively) number
of 1’s are sent, thereby enabling the receiver to detect single bit errors.
Default: No parity
– Stop bits: Number of stop bits. Possible values are 1 and 2 bits. The
stop bits define the interval until the next character can be transmitted,
and are sent as logical 1 (compare with the start bit, which is sent as a
logical 0). Default: 1 stop bit
❼ Flow control
– Hardware flow control: (RS-232 only) Hardware flow control using RTS/CTS.
Explained further in
. Default: Disabled
– Software flow control: Software flow control using XON/XOFF. Explained
further in
. Default: Disabled