Section 40.2.3, Section 40.2.4, Section 40.2.5 – Westermo RedFox Series User Manual
Page 937

Westermo OS Management Guide
Version 4.17.0-0
40.2.3
Setting Serial Port
Syntax [no] port
Context modbus context
Usage Set serial port, e.g., use ”port 1” to select serial port 1 on a single slot
unit, or ”port 1/1” to select serial port 1 in slot 1 of a slotted WeOS unit.
You can use the ”show serial” command in Admin Exec (see
mode to list information your serial ports, including the serial port numbers.
Default values Disabled (”no port”)
Error messages None defined yet.
40.2.4
Setting Serial Protocol
Syntax [no] serial-protocol
Context modbus context
Usage Set Serial protocol (RTU or ASCII).
Default values rtu
Error messages None defined yet.
40.2.5
Setting listen interface and port
Syntax [no] listen
Context modbus context (server mode only)
Usage Setting local interface and TCP port to listen to. Acceptable port range
is in range <0-65335>, where ”port 0” results in using the default port
number (502).
Only applicable when configuring the Modbus Gateway in ”server” mode
(see
Default values Disabled (”no listen”) When enabled, the default port is 502.
Error messages None defined yet.
➞ 2015 Westermo Teleindustri AB
937