53-1002749-01
ZEUS-1004
5
ZEUS-1004
Message
S
good_addr:0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Reboot the system at the next maintenance window. If the problem persists, replace the blade.
ZEUS-1005
Message
S
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a memory allocation failure in the software.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the control
processor (CP) blade.
ZEUS-1015
Message
Port re-initialized due to Link Reset failure on internal Port S
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the port was re-initialized due to link reset failure.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.