Sec-1166, Sec-1167, Sec-1168 – Dell POWEREDGE M1000E User Manual

Page 749

background image

Fabric OS Message Reference

727

53-1002749-01

SEC-1166

5

Recommended

Action

Wait a few minutes and try the command again.

SEC-1166

Message

Non FCS tries to commit failover.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1167

Message

Another FCS failover is in process. Command terminated.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that because another failover is already in progress, this failover attempt cannot proceed.

Recommended

Action

Verify the security event was planned. If the security event was planned, retry fabric configuration server
(FCS) failover after the current failover has completed, if this switch should become the primary FCS. If
the security event was not planned, take appropriate action as defined by your enterprise security policy.

SEC-1168

Message

Primary FCS failover is busy. Please retry later.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.