beautypg.com

Spc-3006, Spc-3007 – Dell POWEREDGE M1000E User Manual

Page 808

background image

786

Fabric OS Message Reference

53-1002749-01

SPC-3006

5

SPC-3006

Message

S, : DEK rewrap error: status code>, DEK: octet 4>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates data encryption key (DEK) rewrap error. The SP status code variable specifies the cause of the
error:

2 - Invalid input data encryption key (DEK) format

14 - Rewrapping not allowed: primary key encryption key (KEK) generation is in progress

31 - DEK could not be wrapped

32 - DEK could not be unwrapped

33 - FGPA error upon inject

73 - Invalid KEK format

Recommended

Action

For status code 14, complete primary KEK generation; otherwise, contact your switch service provider.

SPC-3007

Message

S, : DEK create error: status code>, info: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an error in creating data encryption key (DEK). The SP status code variable specifies the cause
of the error:

2 - Invalid input data encryption key (DEK) specification

14 - Creation not allowed: primary key encryption key (KEK) generation is in progress

21 - No primary KEK exists with which to wrap the DEK

31 - DEK could not be wrapped

73 - Invalid KEK format

other - Internal error

Recommended

Action

For status code 14, complete primary KEK generation; otherwise, contact your switch service provider.