Fabric OS Message Reference
597
53-1002749-01
LFM-1004
5
LFM-1004
Message
HA is out of sync for opcode
Message Type
LOG | FFDC
Severity
CRITICAL
Probable Cause
Indicates loss of high availability (HA) sync with remote control processor (CP).
Recommended
Action
Collect the supportsave information using the supportsave command and contact the Brocade technical
support.
LFM-1005
Message
Logical port
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified logical port is disabled for an internal logging purpose. This could be due to
port segmentation.
Recommended
Action
Check the reason for port disable using the switchShow command, and take appropriate corrective
action.
LFM-1006
Message
The switch with domain
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the firmware version on the specified switch is not compatible with XISL.
Recommended
Action
Check the release notes to verify if this firmware is compatible with XISL. If it is not, remove the switch
from the fabric.