beautypg.com

Flod messages, Flod-1001, Flod-1003 – Dell POWEREDGE M1000E User Manual

Page 448: Flod-1004

background image

426

Fabric OS Message Reference

53-1002749-01

FLOD-1001

5

FLOD Messages

FLOD-1001

Message

Unknown LSR type: port , type .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the link state record (LSR) type is unknown. The following two LSR header types are the
only known types:

1 - Unicast

3 - Multicast

Recommended

Action

No action is required; the record is discarded.

FLOD-1003

Message

Link count exceeded in received LSR, value = .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the acceptable link count received was exceeded in the link state record (LSR).

Recommended

Action

No action is required; the record is discarded.

FLOD-1004

Message

Excessive LSU length = .

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates that the link state update (LSU) size exceeds the value the system can support.

Recommended

Action

Reduce the number of switches in the fabric or reduce the number of redundant inter-switch links (ISLs)
between two switches.