Ns-1010, Ns-1011, Ns-1012 – Dell POWEREDGE M1000E User Manual
Page 654

632
Fabric OS Message Reference
53-1002749-01
NS-1010
5
NS-1010
Message
CSCTL mode enabled on port
this port.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that class-specific control (CS_CTL) mode has been enabled on the specified port that has
devices as members of a quality of service (QoS) zone.
Recommended
Action
Remove the CS_CTL configured devices from the QoS zone.
NS-1011
Message
NS has detected a failover flag disabled TI zone in a base switch
fabric ID
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a failover-disabled traffic isolation (TI) zone has been detected in a base switch fabric.
Recommended
Action
Enable the failover flag or remove the TI zone with the disabled failover flag because the routing may not
be set up correctly.
NS-1012
Message
Detected duplicate WWPN [
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the devices with the same World Wide Port Name (WWPN) have been removed from the
Name Server database.
Recommended
Action
Verify the device reported with duplicate WWPN.