Em-1020, Em-1028, Em-1029 – Dell POWEREDGE M1000E User Manual
Page 306

284
Fabric OS Message Reference
53-1002749-01
EM-1020
5
EM-1020
Message
Unit in
Ethernet switch service is not enabled. Please run
Message Type
FFDC | LOG
Severity
ERROR
Probable Cause
Indicates that a blade inserted in the specified slot requires the Ethernet switch service, which is not
enabled. The blade is faulted.
Recommended
Action
Execute the fosconfig --enable ethsw command to enable the Ethernet switch service. Note that this is
a disruptive command, which requires the system to be restarted. Otherwise, remove the blade.
EM-1028
Message
HIL Error:
Message Type
FFDC | LOG
Severity
WARNING
Probable Cause
Indicates a problem accessing the data on the World Wide Name (WWN) card field-replaceable unit
(FRU) or the WWN card storage area on the main logic board.
The problems were encountered when the software attempted to write to the history log storage to record
an event for the specified FRU. The return code is for internal use only. This can indicate a significant
hardware problem.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port.
Recommended
Action
If the problem persists, restart or power cycle the switch.
If the problem still persists, replace the WWN card, or the switch (for non-bladed switches).
EM-1029
Message
Operational status (
access is being retried.
Message Type
LOG
Severity
WARNING
Probable Cause