Ps-1006, Ps-1007, Ps-1008 – Dell POWEREDGE M1000E User Manual
Page 684

662
Fabric OS Message Reference
53-1002749-01
PS-1006
5
PS-1006
Message
Failed to add fabricmode toptalker monitors on domain=
end-to-end monitors are configured on this switch.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that end-to-end monitors are configured on the switch.
Recommended
Action
Delete end-to-end monitors on the switch and re-install the fabric mode Top Talker monitor. End-to-end
monitors and fabric mode Top Talker monitors are mutually exclusive.
PS-1007
Message
Failed to add Fabricmode Top Talker on domain=
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that FC Routing (FCR) is enabled on the specified fabric.
Recommended
Action
Top Talker cannot be installed on a fabric with FCR service enabled. In case Top Talker must be installed
on a fabric, disable FCR using the fosconfig --disable fcr command.
PS-1008
Message
Failed to delete fabricmode Top Talker monitor on domain
reason:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the fabric is not stable, the domain is not reachable, or the resource is not available.
Recommended
Action
Wait for the fabric to become stable and then execute the perfttmon --delete fabricmode command.