Zeus messages, Zeus-1001, Zeus-1002 – Dell POWEREDGE M1000E User Manual
Page 911: Zeus-1003

Fabric OS Message Reference
889
53-1002749-01
ZEUS-1001
5
ZEUS Messages
ZEUS-1001
Message
Port
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.
ZEUS-1002
Message
Port
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error. All ports on the blade or switch will be disrupted.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.
ZEUS-1003
Message
S
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Reboot the system at the next maintenance window. If the problem persists, replace the blade.