Anv-1007, Anv-1008, Anv-1015 – Dell POWEREDGE M1000E User Manual
Page 164
142
Fabric OS Message Reference
53-1002749-01
ANV-1007
5
ANV-1007
Message
S
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that Anvil Pass 1 is running out of free buffers, which may cause chip fault.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
ANV-1008
Message
S
entry.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the Media Access Control (MAC) VLAN ID (VID) classifier table is full and no more entries
can be added.
Recommended
Action
Delete some of the existing unused rules using the portcfg arp command and then add new entries.
ANV-1015
Message
Port reinitialized due to Link Reset failure on internal port S
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port is re-initialized due to link reset failure.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.