170

Fabric OS Message Reference

53-1002749-01

BL-1019

5

BL-1019

Message

Slot , retry , internal port retry initialization,
.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the slot had internal ports that are not online. Initiated a retry on ports that failed to go
online.

Recommended

Action

No action is required.

BL-1020

Message

Switch timed out initializing the chips.

Message Type

LOG | FFDC

Severity

CRITICAL

Probable Cause

Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips.

Recommended

Action

Reboot or power cycle the switch. If the message persists, replace the switch.

BL-1021

Message

Retry , internal port retry initialization, retrying initialization>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the switch had internal ports that are not online. Initiated a retry on ports that failed to go
online.

Recommended

Action

No action is required.