Port-1005, Port-1006, Port-1007 – Dell POWEREDGE M1000E User Manual
Page 680

658
Fabric OS Message Reference
53-1002749-01
PORT-1005
5
PORT-1005
Message
Slot
portCfgLport to clear configuration.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the specified port is configured to be an L_Port, but the port does not support L_Port. If an
L_Port is connected, then the port will be disabled because the port does not support L_Port. If an
E_Port or F_Port is connected, then the port will not come up because it is configured to be an L_Port.
Recommended
Action
Execute the portCfgLport command to clear the L_Port configuration.
PORT-1006
Message
Configuration changed for port (ID:
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates the configuration changes were made to an offline port in the No_Module or No_Light state.
Recommended
Action
No action is required.
PORT-1007
Message
Port (ID:
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates a port has been reconfigured with a different name.
Recommended
Action
No action is required.